Solar wiring isn’t something most homeowners think about — until something goes wrong. While panels, inverters, and batteries get the most attention, the wiring that connects your entire solar system is just as important. In fact, wiring issues are one of the top causes of solar failures in Texas, especially as systems age and weather conditions put extra stress on rooftop components.

The challenge is that wiring problems are almost always hidden. You can’t see them from the ground, and your monitoring app won’t always catch them early. Many homeowners don’t realize they have wiring issues until their system shuts down, production drops sharply, or the inverter starts showing confusing error messages.

This blog breaks down the most common solar wiring problems, how they impact your system, what warning signs to watch for, and why professional diagnostics are essential for keeping your system safe and efficient in the Texas climate.

Why Solar Wiring Issues Are So Common in Texas

Texas is one of the most challenging environments for rooftop solar wiring due to:

  • Extreme summer heat
  • Strong windstorms
  • Frequent hail
  • Rapid temperature swings
  • Wildlife activity
  • Roof movement
  • Intense UV exposure

Over time, these conditions weaken wiring, connectors, and conduit — especially systems installed without careful attention to code compliance or long-term durability.

This is why Sunaura Solar specializes in code-compliant electrical work, clean workmanship, and safe rooftop handling to protect homeowners from these issues.

1. Loose Connections (One of the Most Common Issues)

Loose wiring happens when connectors are not properly tightened during installation or when they loosen over time due to:

  • Roof expansion and contraction
  • Temperature swings
  • Wind vibration
  • Failing connectors
  • Wildlife interference

How loose connections impact your system:

  • Intermittent production
  • Inverter shutdowns
  • Voltage irregularities
  • Arc faults (dangerous)
  • Hot spots
  • String-level failures

Loose connections often start small and become worse over the years. Because they occur beneath the panels, homeowners don’t notice until performance drops significantly.

2. Damaged or Chewed Wiring (Wildlife Damage)

Squirrels, rats, raccoons, and birds are notorious for damaging solar wiring.

They chew:

  • Insulation
  • DC wiring
  • Rapid shutdown cables
  • Optimizer wires
  • Monitoring cables

They also build nests, which trap moisture and heat.

Common symptoms of wildlife wiring damage:

  • Random dips in production
  • Repeated inverter restarts
  • Partial string failure
  • Monitoring outages
  • Burning smell or buzzing sounds
  • Visible nests under the array

Without protection or regular maintenance, wiring damage from wildlife becomes a major long-term issue.

3. UV Damage to Exposed Wiring

Certain wiring components under the array are protected, but exposed wiring can degrade from Texas sunlight.

UV damage causes:

  • Brittle insulation
  • Cracking
  • Exposed copper
  • Electrical faults
  • Increased fire risk

UV damage is especially common in systems installed with poor cable management or inadequate protection.

4. Water Intrusion Into Conduit or Connectors

Heavy storms, wind-driven rain, and roof leaks can push water into electrical pathways.

Water intrusion leads to:

  • Corrosion
  • Ground faults
  • Rusted connectors
  • Short circuits
  • Failed rapid shutdown devices

Many homeowners don’t discover this problem until they see error codes or major production drops after storms.

5. Poor Quality or Incorrect Connectors

Not all connectors are compatible with each other. Unfortunately, many low-quality installations mix components, leading to:

  • Voltage mismatch
  • Loose locking mechanisms
  • Connector burnouts
  • String-level shutdowns
  • Melting or arcing at the connection point

These issues often appear after 2–5 years of operation.

6. Improper Wire Routing and Poor Cable Management

Clean workmanship is essential in rooftop solar — especially in DFW where wind and heat constantly move roof structures.

Poor cable routing causes:

  • Wires hanging loose
  • Cables rubbing against shingles
  • Insulation wear
  • Conduit separation
  • Increased wildlife access

Over time, these problems worsen and lead to electrical failures.

7. Undersized or Incorrect Wire Gauge

Some contractors cut corners by using wiring that isn’t designed to handle the electrical load.

Undersized wiring leads to:

  • Voltage drop
  • Overheating
  • Inverter inefficiency
  • Reduced system lifespan
  • Fire hazards

This problem usually becomes more noticeable as the system gets older and heat stress increases each summer.

8. Damaged Junction Boxes or Loose Lugs

Junction boxes protect wiring transitions between panels, strings, and conduit. When these boxes become loose, cracked, or water-damaged, they cause:

  • String failures
  • Arc faults
  • Ground faults
  • Short circuits

Many of these issues can only be seen by removing panels — which is why inspections are critical.

9. Hail-Related Wiring Damage

Texas hailstorms are known for damaging:

  • Panel backsheets
  • Junction boxes
  • Wire insulation
  • Exposed connectors

Even small cracks in wiring insulation can lead to long-term electrical instability.

10. Incorrect Wiring Polarity or Crossed Strings

This is an installation error — but unfortunately, it’s common.

Incorrect polarity or string configuration leads to:

  • Extremely low production
  • Rapid inverter shutdowns
  • Fault codes
  • Long-term component stress

Some homeowners operate with crossed strings for years without realizing they’re losing power every day.

Warning Signs You Have a Wiring Problem

Wiring issues often mimic other solar problems, so it's important to recognize the signs.

Production-related signs:

  • Lower output on sunny days
  • Inconsistent production curves
  • Strings producing uneven numbers
  • Sudden production drops

Inverter-related signs:

  • Repeated restarts
  • “Arc fault” messages
  • “Ground fault” messages
  • Overvoltage / Undervoltage warnings
  • Delayed startup

Visual signs (from the ground):

  • Birds around panels
  • Panels shifting after storms
  • Conduit separating from roof
  • Visible wires near edges of array

Monitoring signs:

  • Random dips or gaps in data
  • Entire strings dropping offline
  • Communication failures

If any of these signs appear, wiring should be inspected immediately.

Why Wiring Problems Get Worse Over Time

Unlike panels, wiring does not age gracefully.

Wiring wears out faster due to:

  • Heat expansion
  • UV exposure
  • Roof vibration
  • Moisture
  • Wildlife
  • Corrosion
  • Poor installation practices

Small wiring issues become major faults when:

  • Heat causes further expansion
  • Moisture corrodes connectors
  • Wildlife chews deeper into insulation
  • Panels shift during storms
  • Connectors weaken over time

This is why wiring issues are one of the leading causes of long-term system failure.

How Sunaura Solar Diagnoses Wiring Problems

A professional diagnostic visit includes:

  • String-level voltage testing
  • Current balancing checks
  • Junction box inspection
  • Conduit integrity testing
  • Connector evaluation
  • Thermal imaging to identify hotspots
  • Inverter error log review
  • Monitoring system verification
  • Roof-level wiring tracing

This comprehensive inspection identifies wiring damage that homeowners cannot see.

The Role of Regular Maintenance in Preventing Wiring Failures

Routine solar maintenance prevents 90% of long-term wiring issues.

During maintenance, technicians check for:

  • Loose connectors
  • Corrosion
  • Wildlife damage
  • Weak wire insulation
  • Conduit separation
  • Mounting shifts affecting wiring
  • Early signs of arc faults

Maintenance ensures wiring stays safe, efficient, and durable as the system ages.

When a Solar Detach & Reset Is Required for Wiring Repairs

A Solar Detach & Reset (D&R) is the only way to fully repair wiring issues under the panels.

A D&R allows technicians to:

  • Remove all panels
  • Inspect hidden wiring
  • Replace damaged connectors
  • Repair conduit
  • Remove wildlife nests
  • Reinstall panels correctly
  • Fully restore system wiring safety

If wiring issues are severe or widespread, a D&R is the safest and most effective solution.

Ready to get the most out of your solar system? Contact us today for professional solar service, maintenance, and support.